Heim Chapter 7 Data with Original Data Sources

IRIG 106 Chapter 7 describes a method for transporting variable-length, well-defined data formats in a Chapter 4 pulse code modulation (PCM) stream. IRIG 106 standard packet telemetry defines the method for asynchronously inserting data from one or more data streams into PCM minor frames. The Chapter 7 standard defines various packet types that are used to encapsulate well-defined data formats, including:

  • Chapter 10 packets
  • Chapter 24 TmNS Messages
  • Ethernet frames

Typically many different types of IRIG 106 Chapter 10/11 data types are encoded and sent via Chapter 7 encapsulation. Below are two Chapter 10 recorded data files. One file is a standard Chapter 10 recording of many data types. The second recorded data file is just a recording of the resultant Chapter 7 PCM data stream.

http://www.irig106.org/sample_data/Heim Ch 7.zip

File Name                : Record 01 - TxMDR - short - standalone - 20151210172338_r0002f000.ch10
File Size                : 30,609,864 bytes
Recorder Manufacturer    : ZODIAC Heim
Recorder Model           : 
Recorder Firmware        : 196613
IRIG 106 Version (Data)  : 106-09
IRIG 106 Version (TMATS) : 106-09
Indexing                 : Enabled
Events                   : Enabled
Recording Date / Time    : 12-10-2015-17-23-37
Data Start Time          : 2015/12/10 17:23:37.000
Data Stop Time           : 2015/12/10 17:23:46.603
Data Types               : Channel  Data Type              (Type Num)  Packet Count
                           -------  ---------------------- ----------  ------------
                                0   User Defined             (0x00)            20  
                                0   TMATS                    (0x01)             1  
                                0   Index                    (0x03)            10  
                                1   Time                     (0x11)            10  
                                3   UART                     (0x50)            24  
                                4   Analog                   (0x21)           151   Packed
                                5   Analog                   (0x21)           151   Packed
                                7   UART                     (0x50)             9  
                               15   Video Format 2           (0x42)           987  
                               16   Video Format 2           (0x42)           249  
                               17   Video Format 2           (0x42)           614  
                               18   Video Format 2           (0x42)           249  
                               19   Video Format 2           (0x42)           988  
                               20   Video Format 2           (0x42)           321  
                               21   Video Format 2           (0x42)           735  
                               22   Video Format 2           (0x42)           321  
                               23   PCM Format 1             (0x09)           967   Throughput
                               24   PCM Format 1             (0x09)           967   Throughput
                               25   PCM Format 1             (0x09)           273   Throughput
                               29   1553                     (0x19)           480  
                               30   1553                     (0x19)           480  
                               33   ARINC 429                (0x38)            30  
                               34   ARINC 429                (0x38)           139  
                               35   ARINC 429                (0x38)           109  
                               36   ARINC 429                (0x38)           178  
                               37   ARINC 429                (0x38)            90  
                               38   ARINC 429                (0x38)           237  
                               39   ARINC 429                (0x38)           149  
                               47   Ethernet                 (0x68)           199  
                               51   PCM Format 1             (0x09)          3223   Throughput
                               54   Analog                   (0x21)          2496   Packed
                               55   Analog                   (0x21)          2496   Packed
                               56   Analog                   (0x21)          2496   Packed
                               57   Analog                   (0x21)          2496   Packed
                               58   Ethernet                 (0x68)          2720  
                               62   Ethernet                 (0x68)           198  
                               67   PCM Format 1             (0x09)           272   Throughput
                               68   PCM Format 1             (0x09)           273   Throughput

Other Notes              : 1	Time IRIG-B
                         : 7	Soft UART Status
                         : 19	MVCR5 Video
                         : 21	MVCR5 Video I-Frame
                         : 23	PCM Mets Format1
                         : 24	PCM Mets Format2
                         : 29	MIL Mets MultiMsg#1
                         : 30	MIL Mets MultiMsg#1
                         : 34	ARINC Mets Format 1
                         : 35	ARINC Mets Format 1
                         : 47	Ethernet Mets SingleMsg
                         : 54	Voice (Sinus 400kHz 900mVpp)
                         : 58	Ethernet Mets MultiMsg
File Name                : Record 01 - Chapter7 Telemetry - Short.ch10
File Size                : 98,740,348 bytes
Recorder Manufacturer    : ZODIAC Heim
Recorder Model           : 
Recorder Firmware        : 196613
IRIG 106 Version (Data)  : 106-09
IRIG 106 Version (TMATS) : 106-11
Indexing                 : Enabled
Events                   : Enabled
Recording Date / Time    : 12-10-2015-16-52-25
Data Start Time          : 2015/12/10 16:52:25.000
Data Stop Time           : 2015/12/10 16:53:25.075
Data Types               : Channel  Data Type              (Type Num)  Packet Count
                           -------  ---------------------- ----------  ------------
                                0   User Defined             (0x00)            60  
                                0   TMATS                    (0x01)             1  
                                1   Time                     (0x11)            61  
                               22   PCM Format 1             (0x09)          1898   Packed with Frame Sync