User Tools

Site Tools


sample_data:synthesized_data

Synthesized Chapter 10 Sample Data

Data Bus Tools GmbH has a suite of software that can synthesize Chapter 10/11 from XML definitions. This capability is useful because it allows creating data files with exact, known content. Errors can also be inserted to allow testing for degenerative cases.

The Ch 10 to XML mapping is defined in RCC document 123-16 IRIG 106 Chapter 10 Programmers Handbook Appendix P.

Below is a set of data sample files created from an XML definition using the Data Bus Tools FLIDAS software application. Each zip file contains both the Chapter 10 data as well as the XML definition that was used to create it. Data Bus Tools provides a free version of FLIDAS that will do the conversion between Ch 10/11 and XML.

Discrete

http://www.irig106.org/sample_data/Discrete.zip

File Name                : Discrete.ch10
File Size                : 2,436 bytes
Recorder Manufacturer    : Data Bus Tools GmbH
Recorder Model           : FLIDAS
Recorder Firmware        : 
IRIG 106 Version (Data)  : 106-15
IRIG 106 Version (TMATS) : 106-15
Indexing                 : Disabled
Events                   : Disabled
Recording Date / Time    : 
Data Start Time          : 2018/09/17 00:00:00.000
Data Stop Time           : 2018/09/17 00:00:00.000
Data Types               : Channel  Data Type              (Type Num)  Packet Count
                           -------  ---------------------- ----------  ------------
                                0   TMATS                    (0x01)             1  
                                1   Time                     (0x11)             1  
                               96   Discrete                 (0x29)             1  
                               97   Discrete                 (0x29)             1  
                               98   Discrete                 (0x29)             1  
                               99   Discrete                 (0x29)             1  

Mil1553_message_types

http://www.irig106.org/sample_data/Mil1553_message_types.zip

File Name                : Mil1553_message_types.ch10
File Size                : 2,404 bytes
Recorder Manufacturer    : Data Bus Tools GmbH
Recorder Model           : FLIDAS
Recorder Firmware        : 
IRIG 106 Version (Data)  : 106-15
IRIG 106 Version (TMATS) : 106-15
Indexing                 : Disabled
Events                   : Disabled
Recording Date / Time    : 
Data Start Time          : 2018/09/18 00:00:00.000
Data Stop Time           : 2018/09/18 00:00:00.400
Data Types               : Channel  Data Type              (Type Num)  Packet Count
                           -------  ---------------------- ----------  ------------
                                0   TMATS                    (0x01)             1  
                                1   Time                     (0x11)             1  
                               32   1553                     (0x19)             5  

PCM_CVSD_throughput

http://www.irig106.org/sample_data/PCM_CVSD_throughput.zip

File Name                : PCM_CVSD_throughput.ch10
File Size                : 7,188 bytes
Recorder Manufacturer    : Data Bus Tools GmbH
Recorder Model           : FLIDAS
Recorder Firmware        : 
IRIG 106 Version (Data)  : 106-15
IRIG 106 Version (TMATS) : 106-15
Indexing                 : Disabled
Events                   : Disabled
Recording Date / Time    : 
Data Start Time          : 2018/09/17 00:00:00.000
Data Stop Time           : 2018/09/17 00:00:00.480
Data Types               : Channel  Data Type              (Type Num)  Packet Count
                           -------  ---------------------- ----------  ------------
                                0   TMATS                    (0x01)             1  
                                1   Time                     (0x11)             1  
                              704   PCM Format 1             (0x09)            25   Throughput

TMATS_Sequence

It is legal (but uncommon) for TMATS to span more than one packet. This sample data file has TMATS that spans two consecutive packet.

http://www.irig106.org/sample_data/TMATS_Sequence.zip

File Name                : TMATS_Sequence.ch10
File Size                : 852 bytes
Recorder Manufacturer    : FLIDAS
Recorder Model           : 
Recorder Firmware        : 
IRIG 106 Version (Data)  : 106-15
IRIG 106 Version (TMATS) : 106-15
Indexing                 : Disabled
Events                   : Disabled
Recording Date / Time    : 
Data Start Time          : 2018/09/18 00:00:00.000
Data Stop Time           : 2018/09/18 00:00:00.000
Data Types               : Channel  Data Type              (Type Num)  Packet Count
                           -------  ---------------------- ----------  ------------
                                0   TMATS                    (0x01)             2  
                                1   Time                     (0x11)             1  
You could leave a comment if you were logged in.
sample_data/synthesized_data.txt · Last modified: 2018/12/18 08:19 by bob

Except where otherwise noted, content on this wiki is licensed under the following license: CC0 1.0 Universal
CC0 1.0 Universal Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki